Introduction
The GP2GP record transfer mechanism enables a patient's record to be electronically transferred directly and securely when they move from one practice to another.
Compliance and Assurance
The compliance baseline for GP2GP and document locations were correct at the time of original publication, but referenced documents can now be found embedded on this page, below. The exceptions to this are the references to the NHS Messaging Implementation Manual (MIM) and External Interface Specification (EIS) (follow these links for details).
View file | ||||
---|---|---|---|---|
|
The GP2GP assurance is split into 2 streams:
- Compliance testing - this tests the spine messaging patterns and functionality
- Interoperability Testing - the testing of the clinically semantic testing of the message payload between different systems
For advice and support on assurance please contact businesspartners@nhs.net or visit https://digital.nhs.uk/services/nhs-business-partners
Requirements
ID | Description | Level | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GP2GP00 | Suppliers must meet the requirements for GP2GP 1.1a |
| ||||||||||||
GP2GP01 | Suppliers must meet the requirements for GP2GP 2.2a
|
| ||||||||||||
GP2GP02 | Suppliers must make available documentation to ensure that suppliers receiving GP2GP messages are fully able to interpret, consume and process the data to minimise data loss and degradation. This must include (but is not limited to):
|
| ||||||||||||
GP2GP03 | Suppliers must provide support to receivers of GP2GP messages to resolve any issues with interpreting,consuming and processing received messages |
| ||||||||||||
GP2GP04 | Suppliers must meet the requirements for GP2GP 2.2b
|
|
Message Fragments and Examples
View file | ||||
---|---|---|---|---|
|
Supplementary specifications
The following supplemental specifications contain additional requirements and guidance for GP2GP implementation:
NPFIT-PC-BLD-0069 24 GP2GP Spine Technical Design v7.1.pdf
NPFIT-PC-BLD-0083.08 GP2GP Response Codes.pdf
NPFIT-PC-BLD-0099.04 GP2GP Handling Missing Attachments.pdf
NPFIT-PC-BLD-0132.03 GP2GP Supplementary Specification on Structured Degrade Handling.pdf
NPFIT-PC-BLD-0134.05 GP2GP Supplementary Specification Representing PMIP Data in GP2GP Messages.pdf
NPFIT-PC-BLD-0158 GP2GP Supplementary Specification Attachment References.pdf
NPFIT-PC-BLD-0163.02 Topic and Category Handling in GP2GP.pdf
NPFIT-PC-BLD-0170.03 GP2GP SS Handling Large Messages.pdf
NPFIT-PC-BLD-0171.02 GP2GP SS Harvesting Management Information.pdf
NPFIT-PC-BLD-0172.02 GP2GP UC1 Transfer Electronic Health Record.pdf
NPFIT-PC-BLD-0173.01 GP2GP UC 2 Harvest and Prepare Management Information.pdf
NPFIT-PC-BLD-0175.03 GP2GP SS Handling A-B-A Transfers v1.3.pdf
NPFIT-PC-BLD-0177.01 GP2GP SS User Experience.pdf
NPFIT-PC-BLD-0178 02 GP2GP Coding Scheme Translation v1.1.pdf
NPFIT-PC-BLD-0180.02 GP2GP Transfer of Patient Facing Service Settings 04.pdf
NPFIT-PC-BLD-181.02 GP2GP Handling the SCR indicator v03.pdf
NPFIT-FNT-TO-IG-DES-0115.01 Statement on Data Retention v1.0.pdf
NPFIT-FNT-TO-TAR-0017.07 Compliance Requirements for Patient Registration.pdf
NPFIT-FNT-TO-TIN-0289.08 GP2GP Supplementary Specification on Handling Attachment Types.pdf
Dependencies
Creating a compliant implementation requires implementing the following dependent interface standards: