Updates to external standards in Hosting and Infrastructure
ID | RM308 |
|---|---|
Version | 1.0.0 |
Type | Roadmap Item |
Contracting Vehicle(s) |
Title | Updates to external standards in Hosting and Infrastructure |
|---|---|
Description | Updating hyperlinks to external standards to the most recent version and removing references to specific editions |
Date Added | Jul 30, 2026 |
Standards and Capabilities | |
Change Route | Managed Capacity - Minor/Patch uplifts |
Change Type | Uplift |
Status | Closed |
Publication Date | Aug 14, 2026 |
Effective Date | Aug 14, 2026 |
Incentives / Funding | No |
Incentive / Funding Dates | N/A |
Background
Some of the external standards referenced within the Hosting and Infrastructure Standard have been superseded over time, meaning that some hyperlinks now direct to outdated versions. The aim of this Roadmap Item is to rectify these outdated hyperlinks where required and remove references to specific versions of the standards.
This also includes patch changes to the Co-location and Provider Data Centre Hosting & Infrastructure Requirements - Security, which follow the same approach. Details of these changes can be made available on request.
Outline Plan
N/A
Summary of Change
Baseline Assurance Requirement ES5.0 updated | ||||||
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
| ES5.0 | ISO 9001 - Quality management systems ISO 9001:2015 specifies requirements for a quality management system when an organisation:
All the requirements of ISO 9001:2015 are generic and are intended to be applicable to any organisation, regardless of its type or size, or the products and services it provides. | MUST | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. |
Hosting & Infrastructure: Further Requirements updated | ||||||
Applicable Contracting Vehicle(s) | ID | Requirement | Level | Category A | Category B | Category C |
| ES7.0 | ISO 14001 Environmental management systems ISO 14001 Environmental management systems ISO 14001:2015 specifies the requirements for an environmental management system that an organisation can use to enhance its environmental performance. ISO 14001:2015 is intended for use by an organisation seeking to manage its environmental responsibilities in a systematic manner that contributes to the environmental pillar of sustainability. ISO 14001:2015 helps an organisation achieve the intended outcomes of its environmental management system, which provide value for the environment, the organisation itself and interested parties. Consistent with the organisation 's environmental policy, the intended outcomes of an environmental management system include: · enhancement of environmental performance · fulfilment of compliance obligations · achievement of environmental objectives ISO 14001:2015 is applicable to any organisation, regardless of size, type and nature, and applies to the environmental aspects of its activities, products and services that the organisation determines it can either control or influence considering a life cycle perspective. ISO 14001:2015 does not state specific environmental performance criteria. ISO 14001:2015 can be used in whole or in part to systematically improve environmental management. Claims of conformity to ISO 14001:2015, however, are not acceptable unless all its requirements are incorporated into an organisation 's environmental management system and fulfilled without exclusion. | MAY | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. |
| ES8.0 | ISO 50001 Energy management systems This document specifies requirements for establishing, implementing, maintaining and improving an energy management system (EnMS). The intended outcome is to enable an organisation to follow a systematic approach in achieving continual improvement of energy performance and the EnMS. This document: a) is applicable to any organisation regardless of its type, size, complexity, geographical location, organisation al culture or the products and services it provides b) is applicable to activities affecting energy performance that are managed and controlled by the organisation c) is applicable irrespective of the quantity, use, or types of energy consumed d) requires demonstration of continual energy performance improvement, but does not define levels of energy performance improvement to be achieved e) can be used independently, or be aligned or integrated with other management systems Annex A provides guidance for the use of this document. Annex B provides a comparison of this edition with the previous edition | MAY | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include one of the following:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. |
| ES9.0 | BS6701 Telecommunications equipment and telecommunications cabling. Specification for installation, operation and maintenance BS6701 Telecommunications equipment and telecommunications cabling. Specification for installation, operation and maintenance If you work in the telecommunications industry, and are responsible for installing, operating or the administration and maintenance of copper or optical fibre cabling or equipment, then this newly-revised standard will be of interest. Conformance to specific aspects of BS 6701 is a requirement of the Wiring Regulations (BS 7671) and is applicable in virtually all premises. In addition, it addresses cabling external to buildings and should be followed by anyone installing cabling. Correctly specified and installed cable management systems ensure that telecommunication cabling performs at its best – so it is important that cable management be considered from the start of a project. In addition to specifying the requirements beyond the scope of the BS EN 50174 series of standards for telecommunications cabling, BS 6701 provides requirements for installing telecommunications equipment. The application of BS 6701 will ensure that equipment is properly set up, which means the customer will be reassured their risk-managed cabling installations work to optimum performance, thus assuring more profitable business practice. As one of the few national standards that are directly linked to the EN 50174 series, BS 6701 could also be used in other countries. It supports all cabling media. | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. | Self-certification with Supporting Evidence Supporting evidence to include:
Note: If your Solution is being hosted by a 3rd party data centre provider, then the above evidence should be in relation to the data centre provider. |
| ES13.0 | BS EN 50600-2-1:2014. BS EN 50600-2-1 Building construction (Minimum availability class 3) | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
|
| ES14.0 | BS EN 50600-2-2:2014 BS EN 50600-2-2 Power distribution (Minimum availability class 3) | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
|
| ES15.0 | BS EN 50600-2-3:2014 BS EN 50600-2-3. Environmental control (Minimum availability class 3) | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
|
| ES16.0 | BS EN 50600-2-4:2015 BS EN 50600-2.4. Telecommunications cabling infrastructure (Minimum availability class 3) | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
|
| ES17.0 | BS EN 50600-2-5:2016 BS EN 50600-2-5. Security systems (Minimum availability class 3) | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
|
| ES18.0 | BS EN 50600-3-1:2016 BS EN 50600-3-1. Management and operational information (Minimum availability class 3) | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
|
| ES19.0 | BS EN 50600-4-1:2016. Overview of and general requirements for key performance indicators (Minimum availability class 3) | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
|
| ES20.0 | BS EN 50600-4-2:2016 Power Usage Effectiveness (Minimum availability class 3) | SHOULD | Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
| Self-certification with Supporting Evidence Supporting evidence to include:
Supporting evidence could include:
|
Co-location and Provider Data Centre Hosting & Infrastructure Requirements - Security: MUST requirements updated |
Patch updates to requirements DSC2.5 and DSC3.2. Details available upon request. |
Full Specification
The updated Hosting & Infrastructure Standard will be added at a later date. Proposed changes can be viewed in the Summary of Change above.
Assurance Approach
N/A - Existing Supplier compliance with the Hosting and Infrastructure Standard will remain in place.