Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

...

minLevel1
maxLevel4
outlinetrue
typeflat
separatorpipe

ID

STD003

Name

External ID

DCB1077

Version

0.1

Link to standard

DCB1077: AIDC for Patient Identification

Standard Type

Data Standard (NHS)

Status

Draft

Effective Date

TBC

...

Requirement ID

Requirement Text

Level

STD003-1

GS1 Compliance (Existing Users)

For hospitals/healthcare providers that are already using ISB 1077 compliant wristbands with a GS1 DataMatrix barcode, the related Change Specification should be reviewed to ensure all changes are understood and can be implemented as specified.

GS1 General Specifications

SHOULD

STD003-2

GS1 Compliance (New Users)

New users wishing to implement DCB1077 must ensure the information standard is reviewed alongside the ISB 0108: AIDC: Automatic Identification and Data Capture standard.

Additionally, new users must review the “GS1 DataMatrix Guideline: Overview and technical introduction to the use of GS1 DataMatrix” to ensure all systems and equipment used to create the barcode is compliant with GS1 Standards. See section 6 of the Implementation Guidance for further information on technical requirements.

MUST

...

Requirement ID

Requirement Text

Level

STD004-1

Compliance to GS1 Standards

To be compliant with DAPB0108, is to be compliant to any relevant GS1 Standards, which means that the AIDC system or product being procured, deployed, and used.

MUST

STD004-2

GS1 Identification keys

Utilise GS1 Identification keys for the required data elements based on the functionality and purpose of the system being considered.

MUST

STD004-3

GS1 Data Carriers

Produce, print, and read GS1 Data Carriers such as barcodes or EPC/RFID tags, in accordance with the specifications provided for the intended application.

MUST

STD004-4

Data Format/Carriers

Whilst system design and business processes around collections and data flow remain out of scope for DAPB0108, health IT systems may need to be modified to ensure the data format and data carrier requirements specified can be complied with. The safety implications of any such modifications must be considered by manufacturers of health IT systems as well as those involved in the deployment and use of health IT systems.

MAY

ID

STD070

External ID

DCB0099

Version

0.1

Link to standard

ISB 0099: Patient Identifiers for Identity Bands

Standard Type

Data Standard (NHS)

Status

Draft

Effective Date

...

Requirement ID

Requirement Text

Level

STD0070-1

Core Identifiers

Supplier systems MUST contain the four core identifiers that uniquely identify a patient when used in combination and which must be present on the identity band are:

Last Name, First Name (LASTNAME, firstname)

Date of Birth (DD/MM/YYYY)

Verified NHS Number (3 3 4 format, see NHS Number for full details)

MUST

MAY

...

Requirement ID

Requirement Text

Level

STD0064-1

Verification Status

Applicable Systems must record the verification status of each recorded NHS Number. A verified NHS number has been cross-checked using demographic details on the Personal Demographics Service (PDS)

MUST

STD0064-2

Electronic Communication

Only verified NHS numbers should be sent electronically

SHOULD

STD0064-3

Hard Copy Output

Only verified NHS numbers should be be used when sending a hard copy output

SHOULD