minLevel | 1 |
---|---|
maxLevel | 4 |
outline | true |
type | flat |
separator | pipe |
...
ID | STD001 |
---|---|
External ID | DCB1605: Accessible Information |
Version | 1.0.1 |
Link to standard | |
Standard Type | Mapped Standard |
Status | DraftAlpha |
Effective Date |
|
Description
...
The full specification can be viewed here: DCB1605: Accessible Information - Specification
Requirement ID | Requirement Text | Level |
---|
Requirement ID
Requirement Text
Level
Requirement ID | Requirement Text | Level |
---|---|---|
STD001-1 | Trust Contracts for patient / service user record and administration systems include the requirement for the system MUST adhere to the Accessible Information Standard. | MUST |
STD001-2 | Suppliers' systems SHOULD enable revision / amendment of records made about individuals’ information and communication support needs and, where possible, include prompts for review at appropriate points. | SHOULD |
STD001-3 | Where Suppliers' online systems enable patients or service users to access their own records, there SHOULD be evidence that individuals have viewed and / or contributed to their records with regards to information and communication needs | SHOULD |
STD001-4 | Suppliers' Electronic patient, or service user administration and record systems, SHOULD automatically identify a recorded need for information or correspondence in an alternative format and / or communication support, and flag, prompt or otherwise make this highly visible to staff whenever the record is accessed. | SHOULD |
STD001-5 | Suppliers' Electronic patient or service user administration and record systems, SHOULD automatically identify relevant recorded needs and either automatically generate correspondence or information in an alternative format or enable staff to manually generate correspondence in an alternative format upon receipt of an alert | SHOULD |
STD001-5 | Suppliers' systems used for the recording of individuals’ information and communication needs SHOULD be designed and built with consideration for the clinical safety risks identified in the Clinical Safety Case published alongside this Specification | SHOULD |
STD001-6 | Suppliers' systems MUST enable recording of all of the data items or categories associated with the subsets defined by the Accessible Information Standard, in their specified format. Local systems MAY hold more information than is required by the Accessible Information Standard. | MUST |
STD001-7 | Suppliers' systems SHOULD alert users – in line with other review reminders – when none of the data items / categories in any one of the subsets associated with the Standard has been selected. | SHOULD |
STD001-8 | Suppliers' systems SHOULD support edit checking / quality assurance of data recorded about individuals’ information and communication needs. This MAY include generating an alert or preventing users from populating mutually incompatible data fields (in line with best practice). | SHOULD |
STD001-9 | The Suppliers' systems MUST allow for changes to the data items associated with the Standard over time, including following release of new or amended SNOMED CT, Readv2 or CTV3 codes (where used by relevant systems), and enabling any locally defined additional information to be captured | MUST |
STD001-10 | The Suppliers' systems MUST include functionality to notify staff involved – or to be involved in the near future – in the administration or care of patients or service users of their communication and information needs (and where appropriate the needs of patients’ or service users’ parents or carers). | MUST |
STD001-11 | The Supplier's system MUST automatically identify a recorded need for information or correspondence in an alternative format and / or communication support, and flag, prompt or otherwise make this highly visible to staff whenever the record is accessed. | MUST |
STD001-12 | Where Suppliers' systems automatically generate correspondence, the system MUST automatically identify a recorded need for information or correspondence in an alternative format and in response:
| MUST |
STD001-13 | Where Suppliers' systems automatically generate correspondence, the system SHOULD automatically identify a recorded need for information or correspondence in an alternative format and in response does not produce the standard printed output for sending to the individual, and alerts staff accordingly. | SHOULD |
STD001-14 | The Supplier's system MUST enable records made about individuals’ information and communication support needs to be revised / amended. | MUST |
STD001-15 | The Supplier's system SHOULD prompt for a review of data recorded about individuals’ information and communication needs alongside and concurrent with review of data held in other demographic fields. | SHOULD |
STD001-16 | The Suppliers' systems SHOULD enable recording of all of the data items or categories associated with the subsets defined by the Accessible Information Standard in their specified format. | SHOULD |
STD001-17 | Suppliers' systems SHOULD alert users – in line with other review reminders – when none of the data items or categories in any one of the subsets associated with the Standard has been selected. | SHOULD |
STD001-18 | Suppliers' systems SHOULD support edit checking / quality assurance of data recorded about individuals’ information and communication needs | SHOULD |
STD001-19 | The Suppliers' systems SHOULD generate an alert or prevent or discourage users from populating mutually incompatible data fields when recording individuals’ information and communication needs (in line with best practice). | SHOULD |
STD001-20 | The Suppliers' system SHOULD allow for records made about individuals’ information and communication support needs to be revised or amended. | SHOULD |
STD001-21 | The Suppliers' system SHOULD prompt for a review of data held about individuals’ information and communication needs alongside and concurrent with review of data held in other demographic fields | SHOULD |
ID | STD089 |
---|---|
External ID | Web Content Accessibility Guidelines (WCAG) 2.1 |
Version | 1.0.1 |
Link to standard | |
Standard Type | Guidance |
Status | DraftAlpha |
Effective Date | TBC |
Description
...
Requirement ID | Requirement Text | Level |
---|---|---|
STD0089-1 | WCAG 2.1 IT suppliers systems: Web content SHOULD adhere to the four principles that provide the foundation for Web accessibility: perceivable, operable, understandable, and robust as specified in the W3C guidelines Web Content Accessibility Guidelines (WCAG) 2.1 | SHOULD |
...