Non-Functional Requirements

 

 

 

NFR

Category

NFR ID

REQUIREMENT

DEFINITION

NFR

Category

NFR ID

REQUIREMENT

DEFINITION

Availability and Resilience

NFR-001

Planned Maintenance Period

A fully operational Electronic Patient Record (EPR) Application may have up to 8 hours offline during a planned application maintenance event.

Availability and Resilience

NFR-002

off-line viewing during planned downtime

The patient data held in the Electronic Patient Record (EPR) Application must be available to users whilst the fully operational application is unavailable. The data should be available read only, in an acceptable format, for the user to view easily.

Availability and Resilience

NFR-003

off-line viewing during incident / unplanned downtime

The patient data held in the Electronic Patient Record (EPR) Application must be available to users whilst the fully operational application is unavailable. The data should be available read only, in an acceptable format, for the user to view easily.

Availability and Resilience

NFR-004

click through access during downtime

Data held and managed in other clinical applications, which is usually accessed through the SPR application, must also be available without using the SPR application.

Availability and Resilience

NFR-005

Communication of Planned Outages

No less than 6 weeks notice must be given to users when system unavailability is expected during a maintenance event

Availability and Resilience

NFR-006

Data Retention Periods

Data collected and/or used by a critical clinical application should be retained according to the Trust data retention policy

Availability and Resilience

NFR-007

Roll Back period

The application data storage solution must be configured to enable full restoration (roll back) to any point in the previous 90 days/15 weeks

Availability and Resilience

NFR-008

Roll forward Replay

The SPR application data storage must be configured to enable replay from any point in the previous 90 days

Availability and Resilience

NFR-009

Hardware Maintenance

Applications must be hosted on supported infrastructure, which is suitable for the availability requirements of the application

Availability and Resilience

NFR-010

SPR - RTO 2 Hour

The SPR Application must be recovered to operational status according to the RTO specified in the "Critical (Essential) Systems" document. This is proposed to be set to "within 2 hours".

Availability and Resilience

NFR-011

SPR - RPO 10 minutes

The SPR Application must be populated with data when it is returned to operational status according to the RPO specified in the "Critical (Essential) Systems" document. This is proposed to be set to "no more than 10 minutes lost".

Availability and Resilience

NFR-012

Affected patient records

Patient records affected by planned and unplanned application downtime events must automatically record that a potential gap in data keeping has occurred (medicolegal perspective as well as usability).

Availability and Resilience

NFR-013

Redundant Network

All SPR infrastructure components (diversity of routes, diversity of suppliers, diversity of points of presence) must have at least 2 separate and independent implementations which can be used interchangeably by the SPR application.

Connectivity

NFR-014

CAP assurance

Applications which connect to PDS must assure that the Common Assurance Process has been completed

Infrastructure

NFR-015

Supported Client Environment

The specification and implementation of the SCM environment must be warranted by the Supplier according to the support arrangements and warranted environment specification provided by the supplier

Infrastructure

NFR-016

warranted environment specification

Suppliers must warrant that the warranted environment specification (WES) is up to date and notify the Trust for any changes to the WES at least 3 months in advance of the change.

Infrastructure

NFR-017

End user devices

End User devices (EUD) must meet the minimum specification as provided by the supplier

Infrastructure

NFR-018

Local Infrastructure

connectivity to local networks (for use by application client) and local network provision must meet the minimum specification as provided by the supplier

Infrastructure

NFR-019

Permitted Types of Storage

The SCM solution requires a minimum of 10,000 iops to be available between the data store and application.

Infrastructure

NFR-020

Bandwidth

The network capacity/bandwidth required for on-prem solution should be 1gbps from the client and at least 10gbps between data centres and within (latency < 5ms) as per Dell EMC requirements for vxrail.
The network capacity/bandwidth required for cloud solution must provide equivalence of performance.

Infrastructure

NFR-021

Continuous Operation

The deployed application components must have the ability to use high availability technology and technology patterns to maintain continuous operation.

Infrastructure

NFR-022

Host in a DC

All hardware components of the system not requiring direct access or not providing direct connectivity to the user must be hosted in a data centre.

Infrastructure

NFR-023

Separate Cabinets

The hardware design should house servers which are used to provide resilience in separate chassis and cabinets.

Infrastructure

NFR-024

Separate Data Centre

The hardware design should house servers which are used to provide DR in separate DC

Infrastructure

NFR-025

Production Hardware Less Than 5 Years Old

Solutions must ensure that all production hardware for hosted components remains less than 5 years old.

Infrastructure

NFR-026

Hardware Vendor Support

All hardware and firmware must have a support and maintenance agreement in place whilst it is in active use.

Infrastructure

NFR-027

Operating System Vendor Support

All operating system software must have a valid and current support agreement in place whilst it is in use

Infrastructure

NFR-028

Hypervisor and Virtualisation Service Vendor Support

All infrastructure software must have a valid and current support agreement in place whilst it is in use

Infrastructure

NFR-029

Application gateway

Cloud hosted applications must use an approved application gateway in addition to firewalls monitoring network traffic at the Trust security boundary

Infrastructure

NFR-030

Health and Social Care network

The solution design must show how applications will be able to interact with and access HSCN (Health and Social Care Network), to access services such as PDS, NEMS, NRL

Application Management

NFR-031

Automated Deployment

SPR Application updates must be applied to all application clients at the same time (within a period of 1 hour / during down time?)

Application Management

NFR-032

Verified Deployment

Verification that the update has been applied successfully must be obtained and available for audit

Performance and Scalability

NFR-033

Network Traffic Prioritisation

The design of the solution must include Quality of Service (QoS) components and apply best practice to enable the management of data traffic (network prioritisation) to reduce packet loss, latency and jitter on a network

Performance and Scalability

NFR-034

Network monitoring

Networks hosting the system must be actively monitored by automated systems to ensure correct operation and which must provide alarms where a device or group of devices has a fault.

Performance and Scalability

NFR-035

Peak user volume

The SPR application must be able to support 7000 concurrent users at peak times

Performance and Scalability

NFR-036

sustained user volume

The SPR application must be able to sustain application performance for 3500 concurrent users at any time

Performance and Scalability

NFR-037

data volume

The SPR application must be able to effectively access and search 20TB of data

Performance and Scalability

NFR-038

user response time

System response to a user request must not be longer than 2 seconds in normal use

Performance and Scalability

NFR-039

application processing time

SCM processing time for activity in accessing data and image must be less than 1 second.

Performance and Scalability

NFR-040

action cancelation

Requests which will take longer than 5 seconds must provide the user with a cancel option

Performance and Scalability

NFR-041

Increased Capacity

The design of the solution must support the future state architecture and enterprise growth considerations and apply best practice to enable the implementation of the SPR application

Performance and Scalability

NFR-042

Increases in demand

The solution must provide timely response to changes in demand

for on prem - this is set at maintaining a 20% capacity headroom which can be used within 24 hours
for on cloud - this is set at service agreements in place and the ability to scale the infrastructure within 24 hours

Regulations

NFR-043

Regulatory/Legislative Conflicts

All variances between system specification and legal or professionally accepted best practice relating to cyber security and Information Governance must be fully documented and approved by the Trust before they are implemented.

Regulations

NFR-044

Information Standards Compliance

ICT Applications must not prevent a trust complying with all relevant information standards as defined in the following:

  • Data Protection Act 1998 (incl. GDPR)

  • Human Rights Act 1998

  • Common Law Duty of Confidentiality

  • Health and Social Care Act 2012

  • NHS Codes of Confidentiality and Information Security

Regulations

NFR-045

Information Standards Compliance

ICT Applications must comply with NHSD Clinical risk management standards as defined in the following:

DCB0129

DCB0160

see
https://digital.nhs.uk/services/clinical-safety/clinical-risk-management-standards

Regulations

NFR-046

IG Assessments

A revised "DSP Assertions and Evidence Statement" as specified by the DSP Toolkit assessment process must be completed before the introduction of an application, or a change is made to an existing application, in the production environment.

Security

NFR-047

Implement Authentication

All users of an ICT Application must be authenticated before they are permitted to use the application. User Authentication must use the highest security model available to the application and align with any single sign-on solution in place at the Trust.

Security

NFR-048

End-User Authentication permitted methods

User authentication must use a permitted method from this list:
User is authenticated via Spine and electronically holds a verified Spine identifier
User id and Password
User id and a pre-authorised second factor
User id and Password and a pre-authorised second factor
biometric algorithms (optional user id)
smart card

Security

NFR-049

Security Policy Compliance

All ICT applications must have a data protection impact assessment (DPIA) on record which is reviewed whenever a major change is made. New applications must submit a DPIA before implementation to any production environment

Security

NFR-050

Asset Owner

any new app must have an asset owner identified and they must provide a risk report to the SIRO at least once every 12 months.

Security

NFR-051

Session Timeout

Applications must ensure that access to the system functionality is prevented when the authenticated user has stopped using the application. This rule is subject to consideration on a per area basis e.g. outpatient consultation vs. surgery/theatres.

Security

NFR-052

End point to End Point Authentication

All connections between ICT applications must be configured to authenticate end points before data is shared.

Security

NFR-053

Approved PEN Testing Provision

Penetration testing must be completed for both infrastructure and application by one of the Trust’s approved providers before the ICT application is implemented in the production environment.

Security

NFR-054

Role Based Access Controls (RBACS)

All users of an ICT Application must be assigned an approved Role for that application. Configuration of the Role definition, and rules for role allocation, must be specified by the IAO and approved the SIRO via an information asset risk report.

Security

NFR-055

Implement IG Baseline

Access to data held within ICT systems should be allowed for Informatics, supplier and trust operational users according to need.

Security

NFR-056

Physical Location Hosting

All hosting infrastructure must be physically located in countries with applied UK Data Protection legislation

Security

NFR-057

Appropriate Monitoring Functionality

All ICT applications used in the provision of Trust services must enable scheduled audit and real time protective monitoring at least equal to the risk profile identified within the risk assessment.
Monitoring must include:

  • User specific activity

  • System Commands

  • ‘Significant’ Commands

  • Privilege Commands

  • Information exchanges initiated outside of the organization

  • Information releases to outside of the organization

Security

NFR-058

Secure Audit Trail

All ICT applications used in the provision of Trust services must secure the audit trail of data changes such that it is tamper proof, events are uniquely attributable to a user and non repudiable by both system and user.

Security

NFR-059

Minimum Auditable Events

All ICT applications used in the provision of Trust services must include the following events in audit logs and other data stores as required to satisfy the secure audit trail requirement:

  • High priority events

  • Repeated TLS authentication failures from a single IP address.

  • Any forbidden access attempt recorded between security tiers

  • Account lockouts (due to multiple failures) via the service providing operational

access.

  • Any OSSEC level 071 alert or higher upon any internal server.

  • Detection of any denial of service attack such as XML, DNS, NTP

  • Any login failure on a live server.

  • Any change in the configuration or code.

  • Any unexpected connection attempt on an internal firewall2

  • Any CRITICAL log level raised within the application.

  • An attempt to use a revoked certificate or simultaneous use of a certificate from

multiple addresses.

  • Other interesting events

  • Any TLS authentication failure.

  • Port scans of external addresses.

  • Excessive content lengths to content consumers/listeners.

  • A high3 volume of OSSEC level 04 alerts (or higher).

  • High volume of unexpected connection attempts on any external firewall.

Security

NFR-060

Malware Protection

The ICT production environment used to host any application must incorporate protection from malware.

Security

NFR-061

User Input Minimal

The SCM application must be deployed in a consistent way for all Trust users and not require any user interaction with the update process itself

Security

NFR-062

Patch Management Provision

ICT applications implemented in the production environment must be updated within 14 days of the release of any security patch by the vendor

Security

NFR-063

Deployment of Critical Patch

ICT applications implemented in the production environment must be updated within 24 hours of the release of a critical security patch by the vendor

Security

NFR-064

Security Updates Available

ICT applications implemented in the production environment must not use any subsystem, or rely on any component, which is no longer supported by the supplier

Security

NFR-065

Trusted Applications

All applications and application add-ons must be certified for use and approved for implementation before they are installed in the ICT production environment

Security

NFR-066

Minimum Functionality

Additional functionality without a verified business use, which is available from an authorised ICT application, should be made inoperable through configuration before the application is implemented in the production environment

Security

NFR-067

Automated Deployment & Configuration

Trust environment owners should ensure that operating software for all devices providing the environment are deployed and configured automatically.

Security

NFR-068

Data Management on external devices

Data required by Trust ICT applications operating on mobile devices where the device is not owned by the Trust must encrypt data to a standard not less than AES during the session and delete it at the end of the session.

Security

NFR-069

Data Management on internal devices

Data required by Trust ICT applications operating on any device owned by the Trust must encrypt data to a standard not less than Triple DES or AES during the session. These devices can cache the encrypted data for offline use but must delete the data if it has not been refreshed within a 24 hours period.

Usability

NFR-070

Training Strategy

No major application change should be implemented without a user training strategy

Usability

NFR-071

Application monitoring

Application should enable the ability to monitor user interface failures, navigation failures and incomplete data management transactions.

Usability

NFR-072

User feedback

Application should enable user reporting of user interface issues

Usability

NFR-073

Applications Support notification

Applications should support the ability to configure alerts and enable notifications to the application support team accordingly

Usability

NFR-074

Understanding User behaviour

Applications should provide the ability to monitor the time spent on the "In focus" screen object

Usability

NFR-075

Monitoring applications

Applications should provide the ability to measure the performance of screen loading and screen content refresh (eg changing patient context) activities from the user experience perspective.

Usability

NFR-076

Continuous Usability

Each application must have a usability review whenever a major upgrade or significant change occurs to the system

Accessibility

NFR-077

disabilities and impairments

Applications must make provision for all users' needs, which include (but not limited to) needs described by the GDS "understanding disabilities and impairments user profiles"

https://www.gov.uk/government/publications/understanding-disabilities-and-impairments-user-profiles

Accessibility

NFR-078

Web browser content

Applications providing content via a web browser must ensure the presentation of the content is WCAG 2 compliant

Accessibility

NFR-079

Clinical User Interface

Application user interfaces must be certified compliant with the NHS Digital Service Manual -

https://service-manual.nhs.uk/accessibility/design

Interoperability

NFR-080

External data transfers

All internal and external data transfer must use agreed semantics as appropriate to the data destination

 

 

Â